Welcome to HTFuture!
Optical Switches
Small Size Optical Switches
Multi-port Optical Switches
Multi-port Optical Switches
1x4 Optical Switch
1x12 Optical switch
1x16 Optical Swtich
1x32 Optical Switch
1x64 Optical switch
1x128 Optical Switch
1x8 Optical switch

1x8 Optical switch

1x8 Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.

Specifications:

Parameters

Unit

HT-OSW-8

Insertion Loss

dB

1.0Type: 0.8

Wavelength Range

nm

MM:850±40 / 1300±40,1550

SM:1260 ~ 1650

Test Wavelength

nm

SM:850 / 1300,1550

SM:1310 / 1550

Return Loss

dB

MM ≥ 30   SM ≥ 50

Crosstalk

dB

70

PDL

dB

≤ 0.05

WDL

dB

≤ 0.25

TDL

dB

≤ 0.25

ER (PM swtich)

dB

16 (PoIarization Maintaining switch)

Repeatability

dB

≤ ±0.05

Durability

Cycles

≥ 10 Million

Switching Time

ms

≤ 10(Sequence switch time of adjacent channel)

Optical Power

mW

≤500

Operating Temperature

-5 ~ +70

Storage Temperature

-40 ~ +85

Relative Humidity

%

5 ~ 95

Dimension

mm

135×40×32


Pin Configurations:

DB-9 male connector

Pin No.

Signal Name

I / O

Description

1

D0

Input

TTL, Channel selection bit 0

2

D1

Input

TTL, Channel selection bit 1

3

D2

Input

TTL, Channel selection bit 2

4

D3

Input

TTL, Channel selection bit 3

5

/RESET

Input

TTL, Low level reset to channel 0. High level means channel selection bits are effective.

6

/READY

Output

TTL, Ready (High=Not ready, Low=Ready)

7

ERROR

Output

TTL, Error (High=Error, Low=No error)

8

GND

Input

Ground

9

+5VDC

Input

5.0±5% VDC Power Supply (max 800mA)



Channel Selection Table

Channel

Input

Active Channel

/RESET

D6

D5

D4

D3

D2

D1

D0

8

0

x

x

x

x

x

x

x

0 reset

1

x

x

x

0

0

0

0

COM 1

x

x

x

0

0

0

1

COM 2

x

x

x

0

0

1

0

COM 3

x

x

x

0

0

1

1

COM 4

x

x

x

0

1

0

0

COM 5

x

x

x

0

1

0

1

COM 6

x

x

x

0

1

1

0

COM 7

x

x

x

0

1

1

1

COM 8



Optical Route




Timing Diagram




Dimentions (Unit:mm, DBx male head or female head is defined as the actual mark of the element)



Features:

More Than 8 Channels
Low Loss and High Reliability
Parallel Interface (TTL)
Modularized Design
Epoxy-free on Optical Path


Applications:

Ring Network
Remote Monitoring in Optical Network
Testing of Fiber, Optical Component

Copyright © 2009-2016 HTFuture All Rights Reserved. 